Configure DECnet¶
Use either the DECnet-Plus procedure or the DECnet Phase IV procedure, depending on the version of DECnet installed on your system.
DECnet-Plus¶
Run the DECnet-Plus advanced configuration utility:
$ @SYS$MANAGER:NET$CONFIGURE ADVANCED
Configuration steps:
-
Answer
Yesto continue. -
Select:
3 - Configure devices. -
For EWA0 type
NONE. -
For EWB0 type
NONE. -
Select the default data link name used for LLA0 (LFO).
-
Accept the default routing circuit name of
CSMACD-0Data Link.
Note
Specifying NONE means the physical device is not configured directly. Other non-failover devices may still be configured normally.
DECnet Phase IV¶
-
Start the Network Control Program:
$ MCR NCP -
Answer YES for all parameters:
PURGE LINE EWA-0 PURGE LINE EWA-1 PURGE CIRCUIT EWA-0 PURGE CIRCUIT EWA-1 DEFINE LINE LLA-0 STATE ON DEFINE CIRCUIT LLA-0 STATE ON -
Start DECnet.
-
Start TCP/IP.